dai-ly-ion-science-vietnam-ion-science-viet-nam-tiger-select-portable-benzene-gas-detector.png

Đại lý ION Science Vietnam, ION Science Việt Nam, Tiger Select Portable benzene gas detector ION Science Vietnam, Thiết bị dò khí benzen di động Tiger Select ION Việt Nam

Features

The Tiger Select portable benzene gas detector, displays real-time data, ensuring the final reading represents the full value of actual benzene present. Benzene concentrations are displayed down to parts-per-billion (ppb) levels, giving you accurate, reliable data you can count on.

Tiger Select can also be used in ‘standard Tiger operational mode‘ without the use of a benzene pre-filter tube to deliver active indications of volatile organic compounds (VOCs), including benzene, at concentrations as low as 1 ppb benzene equivalent.

There are 3 gas detection instruments in the Tiger range, the other two include Tiger and Tiger LT.

Specification
Value
Minimum Sensitivity PPM Model Standard running mode 0.1 ppm
TAC 0.01 ppm
Tube mode 0.01 ppm (res. 0.001 ppm)
Maximum Sensitivity PPB Model Standard running mode 0.001 ppm
TAC 0.001 ppm
Tube mode 0.01 ppm (res. 0.001 ppm)
Maximum Reading** Standard mode up to 20,000 ppm or 20,000 mg/m3
Tube mode 200 ppm or 639 mg/m3 benzene
Response Time 130 seconds at 20 °C (variable) progressive indication of benzene breakthrough is displayed in real time
Accuracy*** ± 10 % displayed reading ± one digit benzene (tube mode)
Intrinsically Safe Approvals

II 1G Ex ia IIC T4 Ga

Tamb = – 15 °C ≤Ta ≤+45 °C (with lithium ion battery pack)

Tamb = – 15 °C ≤Ta ≤+45 °C (with alkaline battery pack)

ITS09ATEX26890X

IECEx ITS 10.0036X

3193491 conforms to UL Std. 913, 61010-1 & Certified to CAN/CSA std. C22.2 No. 61010-1

Class 1 Division 1. Approval for Groups A, B, C & D, T4

Battery Life

Li-ion: life up to 24 hours, charge time 6.5 hours

Alkaline: 3 x AA, typically 8.5 hours life

Lamps 10.0 eV Krypton PID lamp
Data Logging* 120,000 data log points including date and time stamp
Communication Direct USB 1.1
Calibration 2 and 3 points calibration (via calibration kit accessory)
Alarm Flashing LEDs Amber (low alarm) Red (high alarm)
Sounder 95 dBA at 300 mm (12″)
Vibration on alarm
Pre-programmed TWA and STEL
Flow Rate ≥ 220 ml/min (with blocked flow alarm)
Temperature Operation: – 20 to 60 °C, – 4 to 140 °F (non intrinsically safe)
Humidity: 0 – 99 % RH (non condensing)
Protection Designed to IP65 (heavy rain)
EMC tested E613261:2006, EN50270:2006 & CFR 47:2009 Class A
Weight and Dimensions Instrument (probe fitted, no tube attached) Height: 465 x Width: 89 x Depth: 61 mm (18.3 x 3.5 x 2.4″)
Instrument weight: 0.75 kg
Standard case: packed weight: 5 kg (176 oz)
Xem thêm thiết bị Tại Đây