Features
The Tiger handheld VOC gas detector provides a dynamic detection range of 0 to 20,000 parts per million (ppm) with a minimum sensitivity of 0.001ppm (1 ppb), offering the widest measurement range of any other VOC detector on the market. This portable, handheld detector has the fastest response time on the market of just two seconds and is just as quick to clear down.
Tiger has been designed for the safe replacement of batteries in hazardous environments. Long-life rechargeable Li-ion batteries give up to 24 hours of use. Fast battery charging allows the instrument to be fully charged in 6.5 hours, while 8 hours of use can be achieved from 1.5 hours charge.
Other instruments in the Tiger range of handheld VOC gas detectors include the low-cost Tiger LT, and the Tiger Select for total aromatic compounds, including benzene.
Specification |
Value |
---|---|
Minimum Resolution* | 1 ppb or 0.001 mg/m3 |
Maximum Reading** | 20,000 ppm or 20,000 mg/m3 |
Response Time | T90 < 2 seconds |
Accuracy*** | ± 5 % display reading ± 1 digit |
Approvals |
II 1G Ex ia IIC T4 Ga Tamb = – 15 °C ≤Ta ≤ +45 °C (with lithium ion battery pack) Tamb = – 15 °C ≤Ta ≤ +45 °C (with alkaline battery pack) ITS09ATEX26890X IECEx ITS 10.0036X 3193491 conforms to UL Std. 913, 61010-1 & Certified to CAN/CSA Std. C22.2 No. 61010-1 Class 1 Division 1. Approval for Groups A, B, C & D, T4 |
Battery Life | Li-ion: life up to 24 hours, charge time 6.5 hours Alkaline: 3 x AA, typically 8.5 hours life |
Lamps | 10.6 eV Krypton PID lamp (standard) 10.0 eV and 11.7 eV available |
Data Logging* | 120,000 points including date and stamp |
Communication | Direct USB 1.1 communication |
Calibration | 2 and 3 point calibration (via calibration kit accessory) |
Alarm | Flashing LEDs Amber (low alarm) Red (high alarm) Sounder 95 dBA at 300 mm (12″) Vibration on alarm programmed TWA and STEL* |
Flow Rate | ≥ 220 ml/min (with blocked flow alarm) |
Temperature | Operating: -20 to 60 °C, -4 to 140 °F (non Intrinsically Safe) Humidity: 0-99% RH (non condensing) |
Protection | Designed to IP65 (heavy rain) EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A |
Weight & Dimensions | Instrument (with probe) Width: 340 x height 90 x depth 60 mm (13.4 x 3.6 x 2.4″) Standard case: 367 x 89 x 90 mm (14.45 x 3.54 x 2.36″) Instrument weight 0.72 kg (1.56 lb) Packed weight: 5.5 kg (12lb) |