Dimensions (H x W x D) 6.5 x 4 x 4
Digital Interface USB 2.0
Outputs 0-20 mA, 4-20 mA, 0-5 V, 0-10 V, Type J, Type K, Type R, Type S
Inputs Digital inputs for emissivity control, ambient background temperature compensation, trigger/hold input
Alarm Relay 48 VAC, 300 mA, optically isolated solid state relay
Accuracy mA/V Output: +/- 2 F (+/- 1 C), TC Output: +/- 3 F (+/- 1.5 C)
Temperature Coefficient mA/V Output: +/- 0.02 F K/K, TC Output: +/- 0.05 K/K
Temperature Resolution (mA/V Output) +/- 0.2 F (+/- 0.1 C)
Cable Length Compatible with 1m (3.3ft) standard, 3m (10ft), 8m (26ft), 15m (50ft), and 30m (100ft) lengths
Output Impedance (T/C Output) 20 Ohms
Min. Load Impedance (mV Output) 10,000 Ohms
Max. Loop Impedance (mA Output) 500 Ohms
Power Supply 8 to 32 VDC, max. 4 W
Housing NEMA 4 (IP65) Die-Cast Zinc
Operational Ambient Temperature 14 to 149 F (-10 to 65 C)
Relative Humidity 10 to 95%, non-condensing
EMC EN 61326-1:2006
Shock IEC 60068-2-27, 50 g, 11 ms, operating, 3 axes
Vibration IEC 60068-2-6, 11 to 200 Hz, 3 g above 25 Hz operating, 3 axes
RAYMI3COMM   MI3 series IR thermometer I/O box with USB 2.0 communications. Select the type of standard sensing heads listed above. 
RAYMI3COMMI   MI3 series IR thermometer I/O box with USB 2.0 communications and sensing head installed. Select the type of standard sensing heads listed above and order as a separate line item. 
RAYMI3COMM4   MI3 series IR thermometer I/O box with USB 2.0 and RS485communications. Select the type of standard sensing heads listed above. For use over long distance or multi-drop networks and requires use of Smart RS485 converter. 
RAYMI3COMMM   MI3 series IR thermometer I/O box with USB 2.0 and Modbus network communications interface. Select the type of standard sensing heads listed above.
RAYMI3COMME   MI3 series IR thermometer I/O box with USB 2.0 and Ethernet network communications interface with installed M12 fieldbus connector and built-in HTTP-Server server . Select the type of standard sensing heads listed above.
RAYMI3COMMP2   MI3 series IR thermometer I/O box with USB 2.0 and Profibus network communications interface with installed 9 pin D-sub fieldbus connector. Select the type of standard sensing heads listed above.
RAYMI3COMMP1   MI3 series IR thermometer I/O box with USB 2.0 and Profibus network communications interface with installed M12 fieldbus connector. Select the type of standard sensing heads listed above.
RAYMI3COMMPN   MI3 series IR thermometer I/O box with USB 2.0 and Profinet network communications interface with installed M12 fieldbus connector. Select the type of standard sensing heads listed above.

 