odac-0182-18700-sensor-measuring-head-measuring-head-odac-18xy-en-pn-zumbach-vietnam.png

ODAC.0182.18700, Sensor Measuring head, Measuring head ODAC 18XY-EN-PN, Zumbach Vietnam, Cảm biến ODAC.0182.18700, Đầu đo 18XY-EN-PN, ODAC.0182.18700 Zumbach Vietnam, 18XY-EN-PN Zumbach Vietnam 

ODAC® 18XY-EN-EN (Ethernet) Option: Local display LOC 01 Option: Local display LOC 01 Host computer Service Ethernet TCP/IP Option: Display unit VISU-Touch Option: Display unit VISU-Touch Option: Display unit VISU-Touch Service Ethernet TCP/IP More applications with RS-485 interface and ANSI protocol Option: Analogue interface Option: Analogue interface or PLC Host RS-232 /-422 /-485 Option: Local display LOC 01 Host computer or PLC System Overviews Option: Digital input for length detector Option: Digital input for length detector Option: Digital input for length detector Supply Supply Supply ODAC® 18XY-EN-DP (Profibus DP), -EN-PN (Profinet IO) or -EN-EI (EtherNet/IP) The built-in processor allows the acquisition and monitoring of the measured values, as well as statistic functions, parameter selection and many other functions. The RS version communicates via the integrated RS interface with a higher level system, like USYS from Zumbach, Host computer (or PLC). The Zumbach protocols ODAC or Host are selectable according to choice. The service interface (Ethernet TCP/IP) is used for configuring the measuring system. The built-in processor allows the acquisition and monitoring of the measured values, as well as statistic functions, parameter selection and many other functions. The EN version communicates via the integrated EN interface with a higher level system. The measured values and parameters are integrated and transferred using a selectable Zumbach protocol (ODAC or Host protocol) in standardized packages of the TCP/IP. TCP/IP allows the data transfer through existing networks such as LANs and others. The built-in processor allows the acquisition and monitoring of the measured values, as well as statistic functions, parameter selection and many other functions. These versions communicate via the integrated Profibus DP, Profinet IO or EtherNet/IP interface with a higher level system. These interfaces are designed for high speed data transfer at the sensor actuator level. At this level, controllers such as programmable logic controllers (or PLC's) exchange data via a fast serial (Profibus DP) or Ethernet (Profinet IO) connection with their distributed peripherals such as drivers, valves or intelligent slaves like ODAC measuring heads from Zumbach. 3 H H H H H H H H Accessories Description Order Number Maintenance kit A34 200 0050 Cleans and keeps the compressed air free of dirt. Features: Filter regulators, submicrofilter, manometer, pressure difference display, automatic condensate emptying and wall fixture. Proximity switch A16 100 0110 The proximity switch is used for the length detection. Main data: – Standard: EN 60947-5-6 (NAMUR, NC) – Switching distance max. 2mm (.08 in.), flush mounting – Ambient temperature: -25...100° C (-13...212° F) – Protection: IP 67, Connection: PVC cable 2 m (6.5 ft.) Guide VR10-ODAC15 ODAC.151.470 With steel rollers (V shape) for measured object diameter up to 10mm (.4 in.). Guide VR1M-ODAC15 ODAC.151.450 With ceramic rollers (V shape) for measured object diameter smaller than 1mm (.04 in.). The measured object must be precisely guided through the middle of the measuring field. Signal cable L2 Bus 1DR22 x 02R A13 252 0150 For the connection between the Profibus DP interface and the customer's data acquisition system. Only for DP version. Connector A10 125 0070 Counter connector for digital input "I/F". Connection of a proximity switch. It is not required, if the analogue interface AI 4-ODAC is already used. Not for ODAC J versions. Local display LOC 01 LOC.011.01000 Is mounted directly on the measuring head. Requires connection cable # ODAC.9167.00004 between LOC 01 and the measuring head. Not for ODAC J versions. Guide VF6-ODAC15 ODAC.151.430 With ceramic rollers (V shape) for measured object diameter up to 6mm (.24 in.). Limiting socket VF15-ODAC15 ODAC.151.420 Used as a device to delimit the measuring field. It has no guiding function! Air curtain LV-ODAC 18XY ODAC.181.910 This air curtain, supplied with compressed air, is used instead of the standard installed splash guards. The air curtain protects the measuring windows from contamination through steam and other "floating" particles. Not suitably for water splashes. Suitable maintenance kit see below. Set of calibration standards ODAC18XY-J-M40 ODAC.9500.38010 Delivered in a protection box, comprising: – Calibration standard holder – Calibration standard ø 0.1 and 10mm – Certificate, other calibration standards on request. Set of calibration standards ODAC18XY ODAC.9500.38000 Delivered in a protection box, comprising: – Calibration standard holder – Calibration standard ø 0.5 and 10mm – Certificate, other calibration standards on request. Air curtain LV.D-ODAC 15-18 ODAC.151.140 Pressurized dust guard. Recommended for wire drawing applications. Metal bushing with ceramic inserts. For the air curtain it's essential to select the corresponding bushing pair: Part no. Bushing Ø Max. Product Ø: B.ODAC.151.1440 1.5 mm (.06 in.) 1.000 mm (.04 in.) B.ODAC.151.1450 2.5 mm (.10 in.) 2.000 mm (.08 in.) B.ODAC.151.1460 3.5 mm (.14 in.) 3.000 mm (.12 in.) B.ODAC.151.1470 4.5 mm (.18 in.) 4.000 mm (.16 in.) B.ODAC.151.1480 5.5 mm (.22 in.) 5.000 mm (.20 in.) B.ODAC.151.1500 6.5 mm (.26 in.) 5.500 mm (.22 in.) B.ODAC.151.1510 8.0 mm (.32 in.) 7.000 mm (.28 in.) B.ODAC.151.1490 9.0 mm (.35 in.) 8.000 mm (.32 in.) B.ODAC.151.1520 10.0 mm (.40 in.) 9.000 mm (.35 in.) B.ODAC.151.1530 11.0 mm (.43 in.) 10.000 mm (.40 in.) B.ODAC.151.1540 12.0 mm (.47 in.) 11.000 mm (.43 in.) ►Suitable maintenance kit see below. Bushing Guide FR13B-ODAC18 ODAC.181.430 With flat ceramic rollers. Used for the precise guiding of flat profiles, having a border length of up to max. 13mm (.51 in.). Adjustment device, DVW 1-ODAC18XYfix +67.5°/-22.5° DVW.101.930 For a continuos adjustment of the inclination of both measuring axes according to the horizontal and vertical axis. Adjustment device, DVW 1 +67.5°/-22.5° DVW.101.900 For a continuos adjustment of the inclination of both measuring axes according to the horizontal and vertical axis. Use only with pivoting device DVW.101.01800 Pivoting support, DVW 1-ODAC 18XY-J/-J-F DVW.101.01800 Mechanical device which pivots the measuring head continuously around the normal measuring axis within +/- 2.5°, 5°, 7.5° or 10° (selectable). With this method, the height and width of the profile can be measured accurately, regardless its angular position (twist). Floor stand ST2-ODAC 18XY ST02.063.65750 Floor stand ST2-ODAC 18XY 45° ST02.063.65760 Vertically adjustable. Line height (H): 900...1200mm, (35.4...47.25 in.) Special lateral supports with rotary holder are available for USYS 20 processors (corresponding data sheets are available on request). Horizontal 45° tilt Floor stand ST1-DVW 1 (horizontal) ST01.392.98000 Floor stand ST1-DVW 1 45˚ ST01.392.98010 Vertically adjustable. Line height (H): 900...1200mm, (35.4...47.25 in.) Horizontal 45° tilt Adjustment device, DVW 1 ± 45° DVW.101.920 For a continuos adjustment of the inclination of both measuring axes according to the horizontal and vertical axis. Use only with pivoting device DVW.101.01800 LED Guide DF4-ODAC15 ODAC.151.500 With ceramic guides. Used for the positioning of products such as monofilaments and similar. For measured object diameter of up to 4mm (.16 in.). Swivel floor stand ST6-ODAC 18XY ST06.141.18000 with heat protection shield ST6-ODAC 18XY "HS Front" ST06.141.18900 Vertically adjustable. Line height (H): 860...1150mm (33.86...45.28in.) Swivel angle: 90° (upward) 35mm (1.38in.) M12x1 Guide FRG18/6B-ODAC18 ODAC.181.490 With flat steel rollers. Best for the precise and centric guiding of round products with diameter of up to 18mm (.71in.) as well as for flat profiles with a border length of up to max. 6mm (.24in.). Guide FR6B-ODAC18 ODAC.181.480-06 With flat ceramic rollers. Best for the guiding of flat profiles, having a border length of up to max. 6mm (.24 in.). Guide FRG6B-ODAC18 ODAC.181.460 With flat ceramic rollers and counter rollers. Used for the precise guiding of flat profiles, having a border length of up to max. 6mm (.24 in.). Guide VF16-ODAC18 ODAC.181.440 With ceramic rollers (V shape) continuously adjustable. Best for the centric guidance of products with diameter of up to 16mm (.63 in.). Guide VR16-ODAC18 ODAC.181.470 With steel rollers (V shape) continuously adjustable. Best for the centric guidance of products with diameter of up to 16mm (.63 in.). Analogue interface AI4-R ODAC.001.100 Interface with 4 analogue, 5 digital and 2 relay outputs. Direct connection of the digital input (proximity switch). Not for ODAC J versions. VISU-Touch VISU.001.01000 The VISU-Touch is a rugged and compact 7" touch screen. This universal PoE (Power over Ethernet) powered touch screen enables display of the integrated web interface of the connected measuring head. It is supplied with a holder for fixing on the measuring head. Not for ODAC J versions. Ethernet cable A15 608 80XX Ethernet network cable cat. 6 S/FTP with RJ45 connectors. (XX in the order number stands for: x 0.1m, e.g. A15 608 8025 stands for 25 x 0.1m and thus a cable that is 2.5m long). Not for ODAC J versions. PoE Injector 48V, 24W A09 502 0070 Power over Ethernet supply for devices that do not support PoE or a long Ethernet cable. Not for ODAC J versions. Air curtain LV.G-ODAC 15 ODAC 15/18XY ODAC.151.940 Protective device for wire drawing application. It is supplied with filtered air by the GE 6 blower unit. The air curtain is supplied with 2.0m (6.5ft.) hose and two hose clamps. Metal bushing as for the air curtain LV.D-ODAC 15-18. Blower unit GE 6 GE.601.060XX Order number: GE.601.06000 (230V/50Hz/0.2kW) Order number: GE.601.06010 (115V/60Hz/0.2kW) Spare filter cartridge CF4 to FL2/FL3/FL4: Order number: A15 105 3230 Heat protection shield, ODAC 18XY-Back (rear) ODAC.181.900 Heat protection shield, HS-ODAC 18XY-Front ODAC.181.920 Heat protection shield, HS-ODAC 18XY-Back (LV) ODAC.181.930

ODAC.0182.18700, Sensor Measuring head, Measuring head ODAC 18XY-EN-PN, Zumbach Vietnam, Cảm biến ODAC.0182.18700, Đầu đo 18XY-EN-PN, ODAC.0182.18700 Zumbach Vietnam, 18XY-EN-PN Zumbach Vietnam

100% Switzerland
Origin

Zumbach Vietnam

Model: ODAC.0182.18700 Sensor  
Measuring head ODAC 18XY-EN-PN    18mm