The Model 4200HT and 4200HT-T High Temperature Embedment Strain Gauges are similar to the standard Model 4200. However, the Model 4200HT is designed for short-term use at temperatures up to 200°C and the Model 4200HT-T is designed for long-term use at temperatures up to 220°C. They are particularly useful for measurements in autoclaved spun concrete piles.

Specifications

Standard Range
3000 µε
Resolution
1.0 µε
Accuracy¹
4200HT | ±0.5% F.S.²
4200HT-T | ±0.5% F.S.
Nonlinearity
<0.5% F.S.
Temperature Range
4200HT | −20 °C to +200 °C
4200HT-T | −20 °C to +220 °C
Active Gauge Length
4200HT | 153 mm
4200HT-T | 148 mm

¹Transducer accuracy established under laboratory conditions. ±0.5% F.S. with standard batch calibration.

²±0.1% F.S. with individual calibration.