flange-load-cell-pd-21-erhardt-leimer-viet-nam.png
Xem thêm thiết bị Tại đây

 

PRODUCT DESCRIPTION
  • Position-independent installation due to various mounting options such as flange bearings, pedestal bearings, inner or outer fastening
  • Maximum operational reliability due to overload protection up to 20 times the nominal measuring force
  • Different shaft diameters from 12 to 65 mm and nominal measuring forces from 0.05 to 10 kN ensure a high degree of flexibility
  • In case of horizontal measuring direction, no influence on the measuring result due to the weight of the roller
  • Good temperature behavior and a high degree of linearity of the measuring elements due to strain gauge application on a flat surface
TECHNICAL SPECIFICATIONS
Accuracy class 0,5
Nominal characteristic (Sensitivity) 1 m V/V
Combined error < 0.5%
Characteristic value tolerance 0.2%
Measuring principle Full bridge strain gauge
Nominal resistance of the bridge strain gauge 700 Ohm
Bridge supply voltage, nominal value 10 V
Bridge supply voltage, max. permissible value 14 V 
Mechanical stop 1.8 to 2.4 FN dep. on type
Operating load 1.8 to 2.4 FN
Limit load 20xFN
Nominal measuring travel 0.1 to 0.2 mm depending on type 
Nominal temperature range -10 °C to +60 °C 
Operating temperature range -10 °C to +90 °C 
Temperature coefficient ±0.3% / 10 K (characteristic value)
± 0.3% / 10 K (zero signal)
Protection class IP 50 
Max. permissible axial transverse force 1xFN 
Weight 2.3 kg (d1 = 17 mm),
3.6 kg (d1 = 25 mm),