dg2006-dg1030-dg2030-dg1060-dg2060-dg1130-dg2130-dg2006-proton-vietnam-may-do-duong-kinh-quet-laser-proton-viet-nam.png

Features

 

  • Non-contact, scanning laser beam diameter measurement.
  • 1 or 2 axis models available in 30, 60 or 130mm maximum diameters.
  • 600 scans per second per axis.
  • Measures wire, cable and cylindrical object diameters (both opaque and transparent such as glass rod) and envelope diameter for braided or helically-stranded cables.
  • Single Scan Flaw Detection (SSFD) for detection of insulation lump and neck flaws.
  • Compact and robust industrial design for use in harsh factory environments (IP65 / NEMA4 protection).
  • Integrates seamlessly via CANbus with Proton Products NEXiSTM CS Series Controllers for diameter driven control of the insulation extrusion process.

Proton Products InteliSENS® DG Series laser scanning diameter gauges provide accurate and repeatable measurements for products manufactured within critical tolerance limits.

Robust industrial design and use of advanced digital signal processing electronics make InteliSENS® DG Series gauges extremely reliable and easy to integrate into production control systems.

Each InteliSENS® DG gauge head features RS232 and CANbus as standard; PROFIBUS, Ethernet/IP or DeviceNET industrial communications interfaces may also be provided as an option integrated within the DG gauge.

Analogue or relay contact outputs may also be provided as an option integrated within the DG gauge or as standard on NEXiS® CS Series Controllers connected to the DG gauge (please click here to see the NEXiS® CS Series of Controllers). The NEXiS® CS series Controllers provide cost effective and accurate diameter control for manufacturers of wire, cable, tubing, piping and many other continuously extruded materials.

Operating Principle

Proton Products InteliSENS® DG series diameter gauges rapidly scan a laser beam across the object under measurement. The laser beam is focused by a receiving lens onto a photodiode and the electrical signal digitally processed by a Proton-designed FPGA processor. The time duration for which the object obscures the laser beam is directly proportional to the object diameter.

DG-Operating-Principle

 

Specification
Minimum
Typical
Maximum
Units
Measurement rate per axis     600 scan/s
         
Operating temperature 5   45 °C
41   113 °F
Relative humidity (at 38°C / 105°F)     90 %
Environmental protection     IP65 -
    NEMA4 -
         
Power supply 15 24 25 VDC
Power consumption     24 W
Measurement units (end-user configurable) mm inch
Standard communications CANbus RS-232
Optional in-gauge interfaces (factory-installed, choice of one) PROFIBUS Ethernet/IP DeviceNET
Analogue outputs Relay contact outputs
Model
DG2006
DG1030
DG2030
DG1060
DG2060
DG1130
DG2130
Units
Axes 2 1 2 1 2 1 2 -
Gate size 30 60 130 mm
1.18 2.36 5.12 inch
Minimum diameter 0.1 0.2 0.5 mm
0.004 0.004 0.02 inch
Maximum diameter 6.5 27 57 130 mm
0.256 1.06 2.24 5.12 inch
Resolution 0.1 1 1 1 µm
Accuracy ±(1µm + 0.008% of object diameter) ±(1.5µm + 0.008% of object diameter) ±(10µm + 0.008% of object diameter) -
Weight 7.5 5 7.5 8 14 10 20 kg
16.5 11 16.5 17.6 31 22 44 lb
Length 260 290 260 425 360 504 674 mm
10.24 11.43 10.24 16.75 14.17 19.68 26.54 inch
Width 66 66 66 68 68 68 68 mm
2.6 2.6 2.6 2.68 2.68 2.68 2.68 inch
Height 270 170 270 212 402 230 654 mm
10.63 6.7 10.63 8.35 15.83 9.06 25.75 inch