Đại lý ION Science Vietnam, ION Science Việt Nam, GasClam 2 Continuous Ground Gas Detector
Hãng sản xuất: ION Science Vietnam
Đại lý ION Science Vietnam, ION Science Việt Nam, GasClam 2 Continuous Ground Gas Detector ION Science Vietnam, Máy dò khí đất liên tục GasClam 2 ION Science Việt Nam
GasClam 2 continuous ground gas monitor collects unmanned continuous ground gas concentration data as well as parameters that are known to control it – subsurface pressure, atmospheric pressure and water level.
Typical applications include:
- Soil contamination and Remediation
- Decontamination
- Emergency Response
- Exploration
Features
Using GasClam 2 continuous ground gas detector provides a hierarchy of financial benefits, these include:
- Reduced number of site visits by a field engineer
- Reducing the overall length of monitoring programmes as legislative data requirements can be met quicker
- The third, and largest savings is made by designing appropriate, rather than over-engineered, solutions based on complete and robust data
Gas | CO2**, CH4**, O2, CO*, H2S*, VOC* |
Method / Type | CO2, CH4: Infrared O2, CO, H2S: Electrochemical VOC: PID |
Range | CO2: 0-100 % CO2: 0-5 % CH4: 0-100% CH4: 0-5% O2: 0-25 % CO: 0-2000 ppm H2S: 0-100 ppm VOC: 0-4000 ppm |
Resolution | CO2 0-100 %: 1 % above 50 % 0.5 % below 50 % CO2 0-5 %: 0.05% above 2.5% 0.025 below 2.5 % CH4 0-100 %: 1 % above 50 % 0.5 % below 50 % CH4 0-5 %: 0.05 % above 2.5 % 0.025 below 2.5 % O2: 0.1 % CO, H2S, VOC: 1 ppm |
Accuracy | CO2 0-100 %, CO2 0-5 %, CH4 0-100 %, CH4 0-5 %: ± 2 % FSD O2: ± 5 % of reading ± 1 digit CO: < ± 3 ppm at 0 ± 5 % at 250 ppm ± 10 % full scale H2S: < ± 1 ppm at 0 ± 2.5 % at 50 ppm VOC: ± 5 % of reading ± 1 digit |
Performance Dual CO/H2S
Method / Type | Electrochemical |
Range | CO: 0 – 500 ppm H2S: 0 – 200 ppm |
Resolution | 1 ppm |
Accuracy | CO: < ± 3 ppm at 0 ± 3 % at 250 ppm H2S: < ± 1 ppm at 0 ± 2 % at 100 ppm |
Environmental
Barometric Pressure | Piezoelectric, 800 to 1250, 1 mBar |
Borehole Pressure | Piezoelectric, 800 to 1250, 1 mBar |
Temperature | Internal Chip, – 5 to + 50 °C or 22 to 122 ° F |
Water Depth | Piezoelectric, 0 – 25 m (Various available) 0.01 m |
Power Options | Internal: Option of Lithium primary cells or Duracell Alkaline D-Cells or Rechargeable battery pack External: Accepts intrinsically safe external power supply for extended and/or rapid monitoring |
Typical battery life (hourly sampling) | Lithium primary cells – 3 months Alkaline cells – 1 month Rechargeable battery pack – 3 weeks |
Weight and Dimensions | 7.5 kg (16. lbs) Overall length: 90 cm (35.4 in) – Borehole tube length: 83 cm ( 32.6 in) Head diameter: 11 cm (4.3 in) – Borehole tube diameter: 4.7 cm (1.85 in) |
Protection | IP68 rated (continuous submersion) |
Operation Temp | – 20 to 50 °C (- 4 to 122 °F) |
Patents and Approvals |
European and World-wide Patented EMC, ATEX 0105 X CE II 2G Ex d ib [ib] IIB T4 Gb IECEx Ex d ib [ib] llB T4 Gb CSA C (US & Canadian Approvals) Class 1, Zone 1 (A)Ex d id llB T4 |
Xem thêm thiết bị Tại Đây |