bxs-standard-solenoid-valves-auto-reset-bifold-vietnam-dai-ly-bifold-tai-viet-nam-nha-phan-phoi-bifold-tai-viet-nam.png
BXS Standard Solenoid Valves, Auto Reset

BXS Standard Solenoid Valves Auto Reset Direct & Indirect Acting, 10 bar, Cv 0.73, Ex emb, Ex d & Ex ia
download pdf brochure

These products are part of the preferred supply ??? for full selection please refer to catalogue.

solenoid valve BXS-04-04-E1-32-NC-00-V-74AT4-24D-36 ¼" NPT Ports, 3 Way 2 Position, Pilot Operated,
Direct Acting, Normally Closed, Spring Return,
24Vdc, Auto Reset Internal Pilot.
3.6 Watt, Cv 0.73, 10 bar.
ATEX ex logo II 2 GDc, Ex emb IIC T4...T3 Gb
IECEx Ex emb IIC T4...T3 Gb
-25°C to +50°C
IP66/IP67 & NEMA 4X
   
BXS-04-04-E1-32-NC-00-V-77A-24D-18 ¼"NPT Ports, 3 Way 2 Position, Pilot Operated,
Direct Acting, Normally Closed, Spring Return,
24Vdc, Auto Reset Internal Pilot.
1.8 Watt, Cv 0.73, 10 bar.
ATEX ex logo II 2 GD, Ex d IIC T4 / T5 / T6
IECEx Ex d IIC T4 / T5 / T6
-60°C to +40°C
IP66/IP67 & NEMA 4X
   
BXS-04-04-E1-32-NC-00-V-78A-260 ¼"NPT Ports, 3 Way 2 Position, Pilot Operated,
Direct Acting, Normally Closed, Spring Return,
Auto Reset Internal Pilot.
260 Ohms, Cv 0.73, 10 bar.
ATEX ex logo II I GD, Ex ia, IIC T4 / T6 Ga
IECEx Ex ia, IIC T4 / T6 Ga
-40°C to +60°C
IP66
 
solenoid valve BXS-04-04-E1-52-XX-00-V-74AT4-24D-36 ¼" NPT Ports, 5 Way 2 Position, Pilot Operated,
Direct Acting, Spring Return,
24Vdc, Auto Reset Internal Pilot.
3.6 Watt, Cv 0.73, 10 bar.
ATEX ex logo II 2 GDc, Ex emb IIC T4...T3 Gb
IECEx Ex emb IIC T4???T3 Gb
-25°C to +50°C
IP66/IP67 & NEMA 4X
   
BXS-04-04-E1-52-XX-00-V-77A-24D-18 ¼"NPT Ports, 5 Way 2 Position, Pilot Operated,
Direct Acting, Spring Return,
24Vdc, Auto Reset Internal Pilot.
1.8 Watt, Cv 0.73, 10 bar.
ATEX ex logo II 2 GD, Ex d IIC T4 / T5 / T6
IECEx Ex d IIC T4 / T5 / T6
-60°C to +40°C
IP66/IP67 & NEMA 4X
   
BXS-04-04-E1-52-XX-00-V-78A-260 ¼" NPT Ports, 5 Way 2 Position, Pilot Operated,
Direct Acting, Spring Return,
Auto Reset Internal Pilot.
260 Ohms, Cv 0.73, 10 bar.
ATEX ex logo II I GD, Ex ia, IIC T4 / T6 Ga
IECEx Ex ia, IIC T4 / T6 Ga
-40°C to +60°C
IP66
 
solenoid valve BXS-04-04-E1-52-XX-E1-V-74AT4-24D- 36-L142 ¼" NPT Ports, Dual Solenoid, 5 Way 2 Position,
Pilot Operated, Indirect Acting, Pilot Return,
24Vdc, Auto Reset Internal Pilot.
3.6 Watt, Cv 0.73, 10 bar.
ATEX ex logo II 2 GDc, Ex emb IIC T4...T3 Gb
IECEx Ex emb IIC T4???T3 Gb
-25°C to +50°C
IP66/IP67 & NEMA 4X
   
BXS-04-04-E1-52-XX-E1-V-77A-24D-30-L142 ¼" NPT Ports, Dual Solenoid, 5 Way 2 Position,
Pilot Operated, Indirect Acting, Pilot Return,
24Vdc, Auto Reset Internal Pilot.
3.0 Watt, Cv 0.73, 10 bar.
ATEX ex logo II 2 GD, Ex d IIC T4 / T5 / T6
IECEx Ex d IIC T4 / T5 / T6
-60°C to +40°C
IP66/IP67 & NEMA 4X
   
BXS-04-04-E1-52-XX-E1-V-78A-260-L142 ¼" NPT Ports, Dual Solenoid, 5 Way 2 Position,
Pilot Operated, Indirect Acting, Pilot Return,
Auto Reset Internal Pilot.
260 Ohms, Cv 0.73, 10 bar.
ATEX ex logo II I GD, Ex ia, IIC T4 / T6 Ga
IECEx Ex ia, IIC T4 / T6 Ga
-40°C to +60°C
IP66
Xem thêm thiết bị Tại đây