100% Germany Origin

Insentiv-Filter Vietnam

TYPE: C41/C52 EV-N/H
DIAGPHRAM P/N: 81738; Material: Hytrel

     

100% Japan Origin

Keyence Vietnam

Model: FT-H10
Cảm biến nhiệt Note: hàng stock ít, check stock khi order

     
     

100% China Origin

Wideplus Vietnam

Model: WP-S403-01-12-HL-P
Digital Controller

     

100% Europe/China Origin

Festo Vietnam

Model: SDE1-D10-G2-R18-C-P2-M8
Pressure Sensor Part Number: 192027

     

100% Germany Origin

DOLD Vietnam

Article number: 0009283
Relay IK8800.12 AC50HZ 230V

     

100% France Origin

Crouzet Vietnam

Code: 88970102
Millenium 3 Serial Programming Cable

100% France Origin

Crouzet Vietnam

Code: 88970104
Millenium 3  Blue Tooth Interface

100% France Origin

Crouzet Vietnam

Code: 88970108
Millenium 3 Memory Cartridge

100% France Origin

Crouzet Vietnam

Code: 88970109
Millenium 3 USB Programming Cable

100% France Origin

Crouzet Vietnam

Code: 88970111
Replace 88970103 et 88970100
Millenium 3 Adapted Solution Software

100% France Origin

Crouzet Vietnam

Code: 88974441
Smart Compact with display and removable terminal blocks 24VDC

     

100% Germany Origin

Bronkhorst Vietnam

Model key : F-111AC-50K-AGD-22-V
Mass Flowmeter
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : N2 (Nitrogen)
Flow range : 1...50 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 2 bar (g)
Temperature : 20...35 °C (calibrated for 27.5 °C)
Seals : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/4" OD compression type
Output signal : RS-232 0...100 % (0...5 Vdc)
Setpoint : RS-232 0...100 % (0...5 Vdc)
Power supply : +15...24 Vdc

100% Germany Origin

Bronkhorst Vietnam

Additional calculated curve for 
Fluid : N2 (Nitrogen)
Flow range : 3.454E-01...17.27 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 2 bar (g)
Temperature : 20...35 °C (calibrated for 27.5 °C)
Conversion table : 11 points
Stored in instrument of pos 001 as Fluid 2

100% Germany Origin

Bronkhorst Vietnam

Swagelok portconnector 1/4x1/4
Swagelok portconnector 1/4"x1/4"

100% Germany Origin

Bronkhorst Vietnam

F-004AC Control valve 
Model key : F-004AC-LUU-21-V
Ingress Protection : IP-40
Fluid : N2 (Nitrogen)
Flow range : 1...50 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : Fixed
Temperature : 20...35 °C
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/4" OD compression type
Outlet connection : 1/8" OD compression type

100% Germany Origin

Bronkhorst Vietnam

F-201CV/F-211CV Mass Flow Controller  
Model key : F-201CV-500-AGD-11-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : N2 (Nitrogen)
Flow range : 6.908E-03...3.454E-01 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS(At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : 0.30 mm
Temperature : 20 °C
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/8" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc

100% Germany Origin

Bronkhorst Vietnam

Additional calculated curve for 
Fluid : N2 (Nitrogen)
Flow range : 3.412E-03...1.706E-01 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Temperature : 20 °C
Conversion table : 11 points
Stored in instrument of pos 004 as Fluid 2

100% Germany Origin

Bronkhorst Vietnam

F-201AV/F-211AV Mass Flow Controller  
Model key : F-201AV-50K-AGD-11-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : H2 (Hydrogen)
Flow range : 1...50 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : 1.50 mm
Temperature : 25...35 °C (calibrated for 30 °C)
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/8" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc

100% Germany Origin

Bronkhorst Vietnam

Additional calculated curve for 
Fluid : H2 (Hydrogen)
Flow range : 3.524E-01...17.62 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Conversion table : 11 points
Stored in instrument of pos 005 as Fluid 2

100% Germany Origin

Bronkhorst Vietnam

F-201CV/F-211CV Mass Flow Controller  
Model key : F-201CV-500-AGD-11-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : H2 (Hydrogen)
Flow range : 0.007...3.524E-01 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : 0.14 mm
Temperature : 25...35 °C (calibrated for 30 °C)
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/8" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc

100% Germany Origin

Bronkhorst Vietnam

Additional calculated curve for 
Fluid : H2 (Hydrogen)
Flow range : 3.48E-03...0.174 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Conversion table : 11 points
Stored in instrument of pos 006 as Fluid 2

100% Germany Origin

Bronkhorst Vietnam

F-111AC Mass Flow Meter  
Model key : F-111AC-50K-AGD-12-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : CO (Carbon monoxide)
Flow range : 1...50 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 2 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Seals : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/4" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc

100% Germany Origin

Bronkhorst Vietnam

Additional calculated curve for 
Fluid : CO (Carbon monoxide)
Flow range : 3.448E-01...17.24 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 2 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Conversion table : 11 points
Stored in instrument of pos 008 as Fluid 2

100% Germany Origin

Bronkhorst Vietnam

Swagelok portconnector 1/4x1/4
Swagelok portconnector 1/4"x1/4"

100% Germany Origin

Bronkhorst Vietnam

F-004AC Control valve  
Model key : F-004AC-LUU-21-V
Ingress Protection : IP-40
Fluid : CO (Carbon monoxide)
Flow range : 1...50 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : Fixed
Temperature : 25...35 °C
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/4" OD compression type
Outlet connection : 1/8" OD compression type

100% Germany Origin

Bronkhorst Vietnam

F-201CV/F-211CV Mass Flow Controller  
Model key : F-201CV-500-AGD-11-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : CO (Carbon monoxide)
Flow range : 6.896E-03...3.448E-01 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : 0.30 mm
Temperature : 25...35 °C (calibrated for 30 °C)
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/8" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc

100% Germany Origin

Bronkhorst Vietnam

Additional calculated curve for 
Fluid : CO (Carbon monoxide)
Flow range : 3.406E-03...1.703E-01 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Conversion table : 11 points
Stored in instrument of pos 007 as Fluid 2

100% Germany Origin

Bronkhorst Vietnam

F-201CV/F-211CV Mass Flow Controller  
Model key : F-201CV-500-AGD-11-V
Product series : EL-FLOW Select
Ingress Protection : IP-40
Material : SS 316L
Multi Fluid Multi Range : Disabled
Fluid : Air
Flow range : 6.912E-03...3.456E-01 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS
(At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : 0.30 mm
Temperature : 25...35 °C (calibrated for 30 °C)
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/8" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc

100% Germany Origin

Bronkhorst Vietnam

Additional calculated curve for 
Fluid : Air
Flow range : 3.412E-03...1.706E-01 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Conversion table : 11 points

100% Germany Origin

Bronkhorst Vietnam

Swagelok portconnector 1/4x1/4
Swagelok portconnector 1/4"x1/4"

100% Germany Origin

Bronkhorst Vietnam

F-111AC Mass Flow Meter  
Model key : F-111AC-50K-AGD-12-V
Product series : EL-FLOW Select; Ingress Protection : IP-40
Material : SS 316L; Multi Fluid Multi Range : Disabled
Fluid : Air; Flow range : 1...50 ln/min
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions)
Calibration certificate : 3-point calibration
Inlet pressure (P1) : 2 bar (g); Outlet pressure (P2) : 2 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C); Seals : Viton 51415
Inlet connection : 1/8" OD compression type
Outlet connection : 1/4" OD compression type
Output signal : RS-232 0...100 % (4...20 mA sourcing)
Setpoint : RS-232 0...100 % (4...20 mA sinking)
Power supply : +15...24 Vdc

100% Germany Origin

Bronkhorst Vietnam

Additional calculated curve for 
Fluid : Air
Flow range : 3.456E-01...17.28 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 2 bar (g)
Temperature : 25...35 °C (calibrated for 30 °C)
Conversion table : 11 points
Stored in instrument of pos 012 as Fluid 2

100% Germany Origin

Bronkhorst Vietnam

F-004AC Control valve  
Model key : F-004AC-LUU-21-V
Ingress Protection : IP-40
Fluid : Air
Flow range : 1...50 ln/min
Inlet pressure (P1) : 2 bar (g)
Outlet pressure (P2) : 1.6 bar (g)
Valve function : Normally Closed
Orifice : Fixed
Temperature : 25...35 °C
Seals : Viton 51415
Plunger : Viton 51415
Inlet connection : 1/4" OD compression type
Outlet connection : 1/8" OD compression type