100% Germany Origin

Balluff Vietnam

BES01C7
BES 516-325-G-S4-C Inductive Sensors

100% Germany Origin

Balluff Vietnam

BES00EF
BES M12ME-PSC40B-S04G-003 Inductive Sensors

100% Germany Origin

Balluff Vietnam

BES01ZN
BES M12MI-PSH80B-S04G Inductive Sensors

     

100% Taiwan Origin

MOXA Vietnam

Model: EDS-205A-T

     

100% Germany Origin

Baumuller Vietnam

Item No.: 00398032
Servomotor; DSD036L-65U4554 0276/0850x1 – PB B04 SKS36
Drawing M0360037A; Torque: M =2.2/1.8 Nm; Speed” n=3000/4500 1/min; Power: P = 700/850 W; Current: I=2.75/2.3 A; Voltage: 540 VDC; Protection Class: Housing IP65, Shaft IP44; With encoder SinCos SRS 50; With temperature Sensor KTY 84-130; With Brake 24V/ 4.0Nm

     

100% Switzerland Origin

Tantronics Vietnam

Part No.: 01-92-34522-A
Programming Analys 2016net with 13 MP

100% Switzerland Origin

Tantronics Vietnam

Replaced by: 00-92-35200-A
Analys 2016net

Analyser with up to 16 measuring points for the measurement of toxic or explosive gas or oxygen with a pump-bypass system.Indication of the gas concentration and the alarm status. To actuate the pre sucktion pump block. To actuate the solenoid valve block with separately pre suck and sample drawing. The system can be adapted to all customized requirements, simply with the password protected menu structure. The configuration of the alarm organization is very simply realized with the integrated alarm matrix.
Technical Data:
Type of device: Analys 2016net; Power Supply: 24V DC; Max. Consumption: 25W; Temperature Range: -20°C to +50°C (short time 60°C); Analog-Output: 1x4-20mA (max. 250 ohms); Digital-Output: 4 Logic Signal for Alarm 1 to 4; 1 Logic Signal for Sensor Fault; 1 Logic Signal for Calibration Mode *; 1 Logic Signal for Calibration Status
1 Logic Signal for Maintenance Alarm; to activate the Solenoid Valve Unit; to activate the Presuction Pump Block; Network: TCP/IP RS232C, CAN Bus (in preparation); Remote Control: with TCP/IP
Data Pick Out: with FTP; Event Recorder: for max. 4000 Events
Temperature Recorder: for max. 4000 Events
* Note dew point of sampling Technical Data IR-Sensor:
Type of Gas: Methane CH4; Measuring Principle: ND-Infrared Detector; Measuring Range: 0-100% LEL; Reaction Time T90: < 10 seconds; Accuracy: 2% FS; Stability: < ± 1% / Month; Zero-Drift: < ± 1% / Month; Temperature Range: -20°C to +50°C (short time 60°C)
Relative Humidity: < 99% RH; Warm up Time: 1 hour
Electrical Connections:
Power Supply: 3 pole Plug; Interface: 2x37 pole Plug; RS232C: 1x9 pole Plug; CAN: 1x9 pole Plug; TCP/IP: 1x RJ45; Remote Control: with Web Interface; Housing Type: 19'' inch rack version; Painting: RAL 7035/5002; Type of Protection: IP30
Note: Analys 2000 that is replaced and 100% compatible with the new Analys 2016net (Tanguard 2000)

100% Switzerland Origin

Tantronics Vietnam

Part No.: 01-91-34496-A
Programming TanGuard 2016net 1 for GT13E (KKS218 replacement for Tanguard 2008); Sensor 1 Exhaust Air Duct Sensor 1 KKS CYQ01CQ212; Sensor 2 Ignitiongas Sensor KKS CYQ01CQ281

100% Switzerland Origin

Tantronics Vietnam

Part No.: 01-91-34523-A
Programming Tanguard 2016net 2 GT13E2 (KKS219 replacement for Tanguard 2008); Sensor 1 Exhaust Air Duct Sensor 2 KKS CYQ01CQ213

100% Switzerland Origin

Tantronics Vietnam

Part No.: 00-91-35100-A
TanGuard 2016net

TanGuard 2016net is the modern microprocessor based gas warning device to monitoring and alerting of toxic and explosive gases and steams for up toeight measuring points into compact 19'' inch rack.The system can be udapted to all customized requirements simply with the password protected menu structure. The attitudes for the attached gas transmitters are made with the internal keyboard. The configuration of the alarm organization is verysimply realized with the integrated alarm matrix
Technical Data:
Type of  Device: TanGuard 2016net; Power Supply: 24V DC; Max. Consumption: depending on Sensor Type max. 50W; Temperature Range: -0°C to +50°C (short time 60°C); Analog-Output: 8x4-20mA (max. 250 ohms); Digital-Output: 8x3 Logic Signal for Alarm 1 to 4; 1 Logic Signal for Sensor Fault; 1 Logic Signal for Calibration Mode* 1 Logic Signal for Calibration Status; 1 Logic Signal for Maintenance Alarm; Network: TCP/IP RS232C, CAN Bus (in preparation); Remote Control: with TCP/IP; Data Pick Out: with FTP; Event Recorder: for max. 4000 Events; Temperature Recorder: for max 4000 Events
Electrical Connections:
Power Supply: 3 pole Plug; Interface: 2x37 pole Plug; RS232C: 1x9 pole Plug; CAN: 1x9 pole Plug; TCP/IP: 1x RJ45; Remote Control: with Web Interface; Housing Type: 19'' inch rack version; Painting: RAL 7035/5002; Type of Protection: IP30

100% Switzerland Origin

Tantronics Vietnam

00-00-30988-A
Certificate of conformity signed and stamped

100% Switzerland Origin

Tantronics Vietnam

00-00-34535-A
Manual TAN-1104 (CD)